NB-IoT network requirements
NB-IoT network requirements
Parking sensors
The average timeOnAir (duration of transmission) shall be max 5,8 sec. To achieve this, please make sure that:
PSM – Power Save Mode is enabled
Release assistance is enabled
Enhanced Coverage Level (ECL) is 0 or 1, but not 2
RSSI is better than -100 dBm
Digital signages
Enhanced Coverage Level (ECL) is 0 or 1, but not 2
RSSI is better than -100 dBm
Network must accept eDRX - 20,40 or 80 seconds
RRC inactivity timer must be set to 15 second or lower value
To increase security, an IPSec connection can also be established to utilize private APN.